Heavy-duty time-delay fuses contain a spring-loaded metal fuse link attached to a solder plug. Watch out: if the fuse for a circuit blows when nothing is connected to it the problem is in the wiring of the circuit itself. In the second photo of the same fuse type you can see into the window and spot the copper strip that is still intact - this fuse is good. Like plug fuses, you might also know which plug fuse is blown by having observed the circuit in the building that has lost power. Get free shipping on qualified 30 amp Fuses products or Buy Online Pick Up in Store today in the Electrical Department. ev A press of the button restores current. Watch out: Consider safety for yourself and other building occupants first. . View cart for details. Read our, Type-S and Type-T Heavy-Duty Time-Delay Fuses, How Do Circuit Breakers Work? A fuse is an electrical safety component that contains a wire that melts or breaks if the current is too high. Type TL Time Delay Glass Plug Fuse 125-Volt 30 Amp (Pack-4) Add to Cart. A cartridge fuse that is blown might or might not be be visually obvious depending on the cartridge fuse brand and model. If the button stays in then the mini-breaker has been re-set. panel, only to have the pullout block disintegrate in his hand. A plug type fuse that is blown will usually be obvious as its clear mica face will be scorched black by the arc flash that occurred when the fuse's internal metal components melted or burned - thus opening (turning off) the electrical circuit that the fuse was intended to protect. For these reasons, always replace fuses with the original amp rating recommended by the device manufacturer. A fast-acting or quick-blow fuse can open the electrical circuit in as little as 0.004 seconds if the fuse is exposed to a short circuit. The Spruce uses only high-quality sources, including peer-reviewed studies, to support the facts within our articles. 70 0 obj You might also know which plug fuse is blown by having observed the circuit in the building that has lost power. Enter your email address to get new posts delivered straight to your inbox! Type W fuses belong on lighting circuits, receptacle circuits, and on other electrical circuits that do not feed high-current electric motors, air conditioners, or water pump motors. Without a time-delay feature, simply starting your garbage disposer or refrigerator would cause a fuse to blow. Thanks! Sign In to access your account information. Class H fuses are rated from 65A to 600A with an interrupting rating (IR) of 10kA for low-interrupt applications. 4 Reviews $ Free Store Pickup Today . Auto Parts v 35a54f35d (p9pjp) cv1440. "How to Use DMM's Safely," Leonard Ogden, Dr. Jess Aronstein, consulting engineer, Poughkeepsie NY, 1991, Rex Cauldwell, master electrician and contributor to the, New York State Central Hudson Gas and Electric Company, G&E/1-2/85 consumer safety pamphlet, Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the. In order for our website to perform as well as possible during your visit. If I had not pulled the fuseshown at lower right in this photo, something interesting would have been missed. On an electric water heater, one of the failures that can occur is a burnt-up and short circuited heater element. Fuses, Breakers & Panel Boxes Keep your home's electrical system safe from damage and overloads with fuse box panels, breakers, and switches, plus a selection of fuses at the most common amp capacities. Some applicants may receive a higher or lower regular annual rate depending on a credit evaluation. If you look into the window of a Type W fuse you'll see that the copper strip inside the fuse has a very narrow section (outlined in yellow in my photo) that will heat up and melt rapidly when an over-current occurs. 2016-06-07T10:52:24-04:00 Fuse Family Bussmann Competitor Fuse Family Competitor . order A plug-fuse: Look at the exposed face of the fuses in the electrical panel. Products shown as available are normally stocked but inventory levels cannot be guaranteed, For screen reader problems with this website, please call 1-800-430-3376 or text 38698 (standard carrier rates apply to texts), Limit the Use of My Sensitive Personal Information, Do Not Sell or Share My Personal Information, Features close sizing to motor load for additional protection, Time delay with a load link for motor startup without opening. Plug fuses are short, round threaded base fuses that screw into position in the fuse box. Both 30A T plug fuses. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover. Offer subject to change without notice. Today you will find T and TL series that offer similar protection but offer . Cookies collect information about your preferences and your devices and are used to make the site work as you expect it to, to understand how you interact with the site, and to show advertisements that are targeted to your interests. Bussman 20 Amp Fuse Out of Stock $1.77 Bussman Glass Tube 2 Amp Fuse Pack Of 5 For Sale $1.83 View Details Bussmann ATL-7-1/2 Out of Stock $1.91 Bussman AGC Glass Tube 30 Amp Fuse For Sale $1.95 View Details Bussman 15 Amp Fuse Pack Of 5 For Sale $2.04 View Details Bussman 1 Amp Fuse For Sale $2.05 View Details 10 Amp Fuse Not for Sale $2.29 The time delay mechanism in a Type T fuse will usually appear to include a spring that is used to pull apart or open the fuse when its fusible link melts. Adobe PDF Library 10.0.1 . When you visit the site, Dotdash Meredith and its partners may store or retrieve information on your browser, mostly in the form of cookies. Yes Mini-breaker fuse rating: 120 volts; up to 20 amps, Cordero, Ismael. InspectAPedia tolerates no conflicts of interest. CANADIAN TIREand the CANADIAN TIRE Triangle Design are registered trade-marks of Canadian Tire Corporation, Limited. A resistance with current flowing through it? Usually the main panel or service panel and sub panels will be located close together. 8The Triangle Rewards Program is owned and operated by Canadian Tire Corporation, Limited. . near you Bussmann T 1 Amp Edison Base Scew in Type Fuse TOO Time Delay. <>>> Was price reflects the last national regular price this product was sold for. Cooper Bussmann 3-Pack 30-Amp Time Delay Plug Fuse. Bonus CT Money collected from online orders will be applied to the members Triangle Rewards account within 5 weeks of the purchase date. Littelfuse Blister Pack 10 Amp Glass Fuse, Littelfuse Blister Pack 15 Amp Glass Fuse, Littelfuse Blister Pack 20 Amp Glass Fuse, Littelfuse Blister Pack 25 Amp Glass Fuse, Littelfuse Blister Pack 30 Amp Glass Fuse, Littelfuse Blister Pack 35 Amp Glass Fuse, Littelfuse Blister Pack 7.5 Amp Glass Fuse. TL Style 30 Amp Plug Fuse (4-Pack) Add to Cart. it was a Buss Type W Amp 10 fuse that are now obsolete, are there TL fuses that are best used when replacing an Amp 10? Bussmann 30 Amp ATC Blade Fuse 5 Piece Part # BP-ATC-30-RP SKU # 32351 Free In-Store or Curbside Pick Up SELECT STORE Home Delivery Standard Delivery Estimated Delivery Mar. . On 2018-12-25 - by (mod) - take care not to cause a fire: do not over-fuse. Using the wrong type of fuse for a circuit can pose a serious fire hazard, so it's important to identify the correct fuse for each circuit. These cartridge fuses are designed to fit into ferrule type bases and can replace blown fuses in circuits found in motorized appliances and equipment such as washers, dryers, furnaces or air conditioners. Ive already replaced them both once with 2 singles and then again with a double . . Cooper-Bussman Fusetron RK5 Dual-Element GFCI Motor Protection, Branch circuits, Sump pumps, Small motors Boiler or furnace, Cooper Bussman FNM Time Delay Midget, Small air conditioner Kitchen circuit Small electric heaters Small electric range to 5kW Small motors to 1Hp, A/C 240V to 36K BTU Clothes Dryer Electric Range to 8kW Electric Water Heater Well Pump 120V, Dual-Element Time Delay GFCI Motor Protection, Eaton Fast-Blow Knife-blade for Class H, K, or R fuse blocks. The "TL" fuses have a time delay built in which will help keep you from having to replace fuses as often. https://www.canadiantire.ca/en/customer-service/ship-to-home.html. Bonus CT Money is collected from online orders will be applied to the Members Triangle Rewards Account within five weeks of the purchase date. A type TL screw-in fuse is one made to delay blowing immediately on sensing an overcurrent. Cartridge fuses are longer cylindrical devices that snap into a clip at either end. Type SL and TL fuse rating: 120 volts; up to 30 amps. Mini-breaker for permanent fuse replacement. Kenneth Kruger: Original author of the sidebar on testing VOM DMM condition: Kenneth Kruger, R.A., P.E. These fuses are designed for use in general lighting and power circuits that do not contain electric motors. The Triangle Mastercard and the Triangle World Elite Mastercard do not have an annual fee. Adobe InDesign CS6 (Windows) See GUIDE to ELECTRICAL TEST EQUIPMENT - neon tester to check for live voltage, continuity tester to check for bad cartridge fuses. 2 pack, 30 A, 250V, indicating fuse, Fusetron Dual Element, time delay, Current Limiting class RK5 fuse, label darkens if fuse has opened, applications, AC power distribution system mains, feeders and branch circuits, motors and motor branch circuits, transformers and other inductive loads, lighting, heating and other non-inductive loads . Some cartridge fuses such as Eaton / Cooper / Bussman FRN-R cartridge Fuses are sold with an easy ID window that shows a deformed line if the fuse is blown . 2016-06-07T10:52:25-04:00 This is intended for informational purposes only and does not modify or invalidate any of the provisions, exclusions, terms or conditions of the policy and endorsements. This site uses Akismet to reduce spam. 2016-06-07T09:52:24-05:00 A70P(AMP)-1 or Type 1 A70P(AMP)-4 or Type 4 A70Q(AMP)-4 or Type 4 A70QS(AMP)-14F A70QS(AMP)-22F A70QS[35-200]-4 1036, from application/x-indesign to application/pdf. The circuit is unsafe and should be left off. The W series is a fast acting fuse, and the TL series is a Time Delay. Note where the electrical wires come to your building - as inside the main panel will usually be close to that same aera. see ELECTRICITY TURN ON AFTER BREAKER TRIP. Type SL fuses work like Type TL fuses but use the smaller-diameter Type-S fuse base to prevent tampering. The offered rate is exclusive of any bonus or promotional offers or redemption transactions. Just don't go the other way. Type T-fuses are a time delay fuse that are also called "slow-blow" fuses. They are used to keep voltage spikes or wiring problems from damaging other wiring or devices.. | Your choice will be saved for one year. : Since you're going to replace the heavier duty fuse with a medium duty fuse, the worst that will happen is that the medium duty fuse will blow more quickly if there is an overload or surge. Cooper Bussmann 2-Pack 30 Amp Time Delay Cartridge Fuse. Watch out: if the cartridge fuses are not removed by pulling out a fuse block like the ones in our photo above, you'll need to use an insulated cartridge pulling tool, usually a plastic clip, to remove the cartridge fuse. Until The fuse is there to limit the current that can flow through the circuit. Shipping fees apply. These fuses are highly sensitive to changes in current flow and don't tolerate temporary overload currents or power surges, so they open within seconds of being exposed to overloads and short circuits. You can determine the correct size or rating for your fuses by noting the wire size of the circuit it is protecting. Midget cartridge fuses include the following, Midget Class CC - rejection versions used for both branch circuit wiring and supplemental device protection, Midget KTK fast acting (quick blow) cartridge fuses. Some fuse blocks have an ON-OFF position. For residents of Quebec, the period between the statement date and the due date for payment is 26 days. The dryer quit last night and the 2 fuses marked 'dryer' in that box are blown. In stock. That's a heater. Only one image can be added per comment but you can post as many comments, and therefore images, as you like. Compare. Mfr Brand Name: BUSSMANN / Catalog No. The only difference between SL and TL fuses is the type of base: the SL fuse has a rejection base, and the TL fuse has an Edison base. In our fuse box photo above, the box uses a combination of a main fuse pull-out at the top of the panel - this removes all electrical power to the building, three 240-Volt fuse block pull-outs, and twelve screw-in type plug fuses. Doing so risks a building fire, property loss, injury or worse. Add to Cart. 2016-06-07T10:52:25-04:00 These fuses are not very pretty, as they've been bouncing around in my electrical toolbox for three decades, kept at hand for an emergency need that has not arisen. Choose a matching replacement fuse of the same type and ampacity. The Top subscription boxes right to your door, 1996-2023, Amazon.com, Inc. or its affiliates, RVMATE 30 Amp 30 Feet RV Lockable Power Extension Cord, Easy Plug in Handle, TT-30P to L5-30R with LED Indicator, 10 AWG, ETL Listed, EyGde 15 Amp to 30 Amp RV Adapter, 4200 Joules Electrical Power Adapter with Surge Protector, Circuit Analyzer Power Guard NEMA 5-15P to NEMA TT-30R for Camper Travel Trailer, GearIT 30-Amp Extension Cord for RV and Auto, (15-Feet) 3-Prong 125-Volt 10/3 STW 10AWG Gauge 3 Wire, NEMA TT-30P to TT-30R, Outdoor Camper Power Cord, MECMO 30 Amp to 30 Amp RV Adapter Cord with Locking Connector Plug NEMA TT-30P to L5-30R, UL Listed RV Power Cord, TT-30P Male Plug to L5-30R Female RV Adapter, 1.5 FT, 10/3 STW, 125 Volts 3750 Watts, SHUNSEN 30 Amp Surge Protector for RV,Adapter Circuit Analyzer with LED Indicator Light, RV Circuit Analyzer 30 Amp to 30 Amp, 2100 Joules for Camper Trailer, Learn more how customers reviews work on Amazon. If you think that's ok, just click "Accept all". If you need to replace your spa's fuses, but are unsure which parts you need to order, please call our Customer Service team at (855) 308-2149 today! 1 to 60A NON / NOS are UL listed as Class K5 - IR: 50kA, while 70A-600A fuses are UL listed as Class H - IR: 10kA. However, just like the SL and TL fuses, the only difference between the S and the T heavy-duty fuses are the bases: type-S has a rejection base; type-T has an Edison base. These articles suggest safety procedures for the electrical inspector, home inspector, or other professionals who examine residential electrical systems. Adobe PDF Library 10.0.1 Afuse box is a type ofelectrical service panel, which is a sort of control boardfor the entire electrical system of a house. PMID:23139454. loyalty program Mini-breakers are also designed for time delay, so they do not trip unnecessarily when motors or appliances start up. If you refuse these cookies, some functionality will disappear from the website. We also noticed rust along the bottom of this panel, raising a possibility of internal damage that is not visible until your electrician opens the panel to examine its interior. $30.99. Using your car's manual or the diagram on your fuse box, you can easily locate the offending fuse. /TMMarks is a registered trademark of Marks Work Warehouse Ltd, used under licence. How do we restore power to the dead circuit? endstream Higher-ampacity fuses will be larger in size than smaller amp-rated cartridge fuses. For example, it stops a person from putting a 20-amp fuse in a 15-amp circuit, a potentially serious mistake. Bussmann series Edison base W plug fuse data sheet no. Conditions apply. xmp.did:07801174072068118DBBAB668637C198 Jim Simmons: Personal communication, J. Simmons to Daniel Friedman, 9/19/2008. You cannot collect paper Canadian Tire Money on bonus offers. For general purpose Edison Base, TL / Littelfuse TLO Plug Fuse. Bussmann 30 Amp Time Delay Loaded Link Rejection Base Plug Fuse, 3-Pack 73 17 offers from $8.22 Product details Is Discontinued By Manufacturer : No Item Weight : 0.8 Ounces Date First Available : January 1, 2016 Manufacturer : BUSSMANN ASIN : B00FV23ELE That is if the blown fuse is 15 Amp replace it with a 15 Amp fuse. Plug fuses like the ones in the photo above show their type and ampacity or size both by color convention - the color of the fuse top - and by printing on the fuse that will give the amps rating and fuse type on the fuse top surface. 2016-06-07T13:51:27.805-04:00 More Options Available $ 12 98 ($ 6.49 /fuse . 15 0 obj O'Reilly Auto Parts carries a variety of fuses for most vehicles. Visit triangle.com for full program rules and Partner location information. What about the other wiring in the panel? 2000-2022 Home Depot. Bob Formisano is a licensed architect and builder with nearly 40 years of experience building new homes and restoring older homes. After viewing product detail pages, look here to find an easy way to navigate back to pages you are interested in. You will not receive a notification when a response to your question has been posted. W Wiredindallas Registered Joined Nov 9, 2018 2,841 Posts "MO^|j!]O7JEK^.zFeE, Specifications and technical details on the Bussmann series W Edison base plug fuse, Bussmann series Edison base W plug fuse data sheet no. You'd replace that with a Type T or Type TL fuse. Watch out: I've made all of these cartridge fuse images the same size. 20 Amp. . Plug fuses were commonly used for overcurrent protection prior to modern-day circuit breakers. Click here to find a S-Type Fuse Identification Continue readingat CIRCUIT BREAKER MAIN or FUSE TEST or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX. uuid:7b34056e-0d4a-43bc-81fb-baa9d6d5e7d5 This allows the fuse to absorb a temporary circuit overload, such as that caused by a brief surge in power demandwhen a motor starts up. What Dangers Lurk Beneath Your Fuse Boards Cover? Rejection base (Type S) fuses will work with Edison-type sockets only when combined with an adapter base that screws and locks into the Edison socket. If your circuit uses 20 amps, a fuse rated for 15 amps will blow right away. RELATED SEARCHES. If the screw in base for the fuse becomes damaged how do you replace it and where do yoy find a replacement part? <>stream
The red arrow under the word "SINK" points to the solder that acts as a heat sink to slow the melting of the narrow copper fusible link, giving a time delay before the fuse will blow. Larry Campbell is an electrical contractor with 36 years of experience in residential and light commercial electrical wiring. Full content visible, double tap to read brief content. The Hartford Steam Boiler Inspection and Insurance Company. Un-screw the plug fuse by turning it counter-clockwise ("lefty-loosie" as my daughter Mara says). No rainchecks. Bussmann Series 5 Count ATC / ATO 30 Amp Automotive Fuse Pack, BP/ATC-30-RP: Package includes 5 count of 30 Amp ATC fuses; Bussmann series ATC fuses are UL Recognized . In my photo above you can see the internal parts of a Type TL slow-blow or time-delay fuse. BUSSMANN Fuse: 30 A Amps, 250V AC, K5, 2. converted The 15 amp fuse is to protect #14 gauge copper wire, 20 amp fuse protect #12 copper wire, and 30 amp for #10 copper wire. These have two mini fuses related to the A/C on the back left of that panel. Type T-fuses use a larger-diameter Edison screw-in base. Bussmann T 8/10 .8 Amp Edison Base Scew in Type Fuse TOO Time Delay. Type T and Type-S are heavy duty fuses for high inrush current applications and typically use a dual-element design. | Copyright 1995-2023 eBay Inc. All Rights Reserved. If one or more of your electrical systems like your radio, power locks, power windows or interior lights aren't working, check the fuse for that system. XREF200 Printed in Canada 599 Norris Crt., Kingston, Ontario, K7P 2R9 Tel. The block is removed from the panel by its handle, the cartridge pulled out and replaced. To collect bonus CT Money you must present a Triangle Rewards card/key fob, or use any approved Cardless method, at time of purchase or pay with a Triangle credit card. It would be helpful to see a sharp photo of the conditions about which you are asking. To cover every domestic or commercial situation, we stock fuses rated from 0.2 amps . Access My Account, Order History, Lists and more here. . Any way I can determine it's rating/specifications so I buy one that will fit? 9 Images about QBGF2015 - 2 Pole Circuit Breaker . 14 Items 1 2 Next Sort By .3 Amp Fuse SKU: X801450 $6.90 Add to Cart Master Spa Fuses 5 Amp Slow Blow (FST) On 2020-03-22 - by (mod) - If the circuit breakers keep tripping, Moma We serve cookies. Mini breakers have a little button that pops out when the circuit is overloaded. There was an error retrieving your Wish Lists. Example: On a $100 (pre-tax) purchase with 25X bonus multiplier a Member would earn a bonus $10 in CT Money (25 x 0.4% x 100). The Edison base (Type T)looks like a light bulb base and fits the standard sockets found in old fuse boxes. HWn}W#_Ce`Z2@49Zr('S89j.'R?%~JZVo'JJXdFjnN~v5'1WQQ\&7/zsJrj'4vgzN/Z,_yrv~}fuxVLzHGeoh
cZ@TUE,)m97EC"X7fzy;nz"b3>}ltFj,CD9E=2dY~ Z/]t:;&9.>wi[,rV|b[fi6BvN| unMfnAcS?^,[vGVUH8+fyjwPUjt/~X|fCn\&NOWJI(%Fl+q[=-z%>~fMq}fY[nzH7!]Py$Y+O3.VC.n\w]J|(ZFO})*[ Residential plug fuses will be as shown from left to right: each protecting a single 120-Volt circuit. Watch out: never try to install a fuse that is rated higher (in amps - that is a bigger number) than the fuse that has blown. The UL-listed plug fuses have Edison bases and are rated for a maximum of 125-Volt. Time-delay, dual-element T Series Edison base plug fuses provide small motor overload protection Volts 125Vac
John In older fuse panels people are too often tempted to get around a frequent problem with blown fuses by installing an over-sized fuse - this is an unsafe action and is a fire hazard. 2023 Copyright Canadian Tire Corporation. : The tire producer / manufacturer of the tires you are buying, and Canadian Tire is responsible for the recycling fee that is included in your invoice. It appears to me that the cover is still there and that it has been latched into the up and open position. But we pose that it may be difficult to find a replacement fuse pull-out for some older fuse panels. Shipping fees and delivery times vary depending on location, size and weight of the item(s) and is only available within the province of the Canadian Tire retail location (Store) from which the item(s) was purchased. from application/x-indesign to application/pdf To properly select glass replacement fuses, the cover of the fusebox should be removed. The inrush current reduces down to normal running current after a few cycles. TESTED. Fuse manufacturers developed plug fuses with time-delay characteristics to compete with new circuit breakers. Customer Reviews, including Product Star Ratings help customers to learn more about the product and decide whether it is the right product for them. In our photo just above the cover has been opened and the inspector (me) has pulled out the two pull-out fuse carriers that each held a pair of cartridge fuses. Hi. If there are multiple appliances connected to the circuit whose fuse is blowing, unplug everything on the circuit. a6126c432d1f28dd7a2f3e9e1b1c523a6117bdc7 Our Lowest Prices of the Year are defined as the period between January 1 to December 31, 2022. Not all items sold at Canadian Tire earn CT Money. He has over 25 years experience in solving facilities and electrical engineering challenges. Watch out: never try to install a fuse that is rated higher (in amps - that is a bigger number) than the fuse that has blown. Should you ever pull the main fuse or switch off the main circuit breaker in the electrical panel? 125V. However, if we do not receive the full minimum due on a statement within 59 days of the date of that statement, or any event of default (other than a payment default) occurs under your Cardmember Agreement, all special payment plans on your account will terminate and (i) you will then be charged interest on the balances outstanding on such plans at the applicable regular annual rate from the day after the date of your next statement, and (ii) the balances outstanding will form part of the balance due on that statement. A slow burn or time delay fuse is used with certain types of electrical appliances. Watch out: Fatal Shock Hazard Warning: Inspecting electrical components and systems risks death by electrocution as well as serious burns or other injuries to the inspector or to others. Wait about 5 minutes to let the fuse cool down. Each month during an equal payments plan you are required to pay in full by the due date that months equal payments plan instalment. Dealers may sell for less. , ASIN Compare . In addition, the T and TL plug fuses offer time-delay performance for For the best experience on our site, be sure to turn on Javascript in your browser. Delivery times may vary, especially during peak periods. If it's normal lights and/or receptacles, it's almost certainly been overfused (fire hazard! These fuses are designed for use in general lighting and power circuits that do not contain electric motors. Instead it's time to get people out of the building and call emergency services. $5.99. Inside a TL fuse you'll see that the time delay mechanism is in essence a large rectangular blob of solder. Apologies for the delay. Type T time delay fuses, shown above as a 15-Amp fuse, are designed to avoid blowing the fuse during the brief current-draw surge that occurs when some motors first turn-on. Qty. endobj COOPER BUSSMANN W-30 30AMP, Fast Acting, Discontinued by Manufacturer, 125V, Plug Type-W, Fuse, 30 amp 4 prong L14-30 generator extension cord, 30Amp to x2 30Amp Y Adapter TT-30P to x2 TT-30R, MICTUNING Heavy Duty Trailer & RV Accessories, Is Discontinued By Manufacturer Need Help? 1036 Balances under $10 are due in full. 20 0 obj By contrast, a Type T fuse can fit into any Edison socket, regardless of the circuit's amperage. What to do if a fuse blows in your electrical panel: Here we describe the types of fuses found in fused electrical panels, the causes of blown fuses, the right fuse size selection, and fuse replacement. Fuse Cross Reference Guide Guide de Correspondance E-mail: info@fusetek.com web: www.fusetek.com Ver. CT Money is collected on the pre-tax amount of the purchase. Local store prices may vary from those displayed. 2 pack, 30 A, 250V, indicating fuse, Fusetron Dual Element, time delay, Current Limiting class RK5 fuse, label darkens if fuse has opened, applications, AC power distribution system mains, feeders and branch circuits, motors and motor branch circuits, transformers and other inductive loads, lighting, heating and other non-inductive loads . This quick review should help you to understand plug fuses and their proper application. Well take a look and remove the review if it doesnt follow our guidelines. Maximum value: 99999. False Interest does not accrue during the period of the plan. Brand Name Voltage (volts) Material Fuse Style Rating Price See All Filters Sort by Recommended Hide Unavailable Products Compare Leviton Fuse P Rated 15 Amp (7) - Not Available for Delivery Not Sold in Stores View Details Compare Leviton Time Delay Fuse 15 Amp (20) - Not Available for Delivery Not Sold in Stores Show details $26.30 $6.32 Minoston Outdoor Timer for Lights with Remote 24 Amazon's Choice in Plug-In Timers 1 offer from $15.70 However in an emergency, if you don't have the right sized fuse, it is safe to install a fuse of lower ampacity. Do not try to grab the fuse directly with your fingers because you may touch live electrical contacts - the shock could kill you. Bussmann 30 amps Dual Element Time Delay Fuse 2 pk . Touching these live wires or allowing them to touch any metal component inside this fuse box is very dangerous. Are some of the edison-base fuses oversized? L x 0.6 In. Rewards are in the form of electronic Canadian Tire Money (CT Money). We carry a complete line of genuine OEM Master Spa fuses, from the .3 amp to the 30 amp. This condition is called over-fusing and can result in the fuse failing to blow before the circuit wiring overheats and potentially catchesfire.